TAYLOR WINFIELD Press-type Projection Welder

  • Machine Specifications

    Stock Number:

    6216

    Transformer:

    50 KVA

    Manufacturer:

    TAYLOR WINFIELD

    Mfg. Model Number

    ENE-18-50

    Voltage:

    440/460/480 Volts, Single Phase

    Throat Depth:

    18 in

    Secondary Volts:

    2.97 - 7.33

    Secondary Amps:

    22,500

    Serial Number:

    82133-C

    Air Type:

    Standard Dual Acting

    Cylinder Diameter:

    5 in

    Max Force:

    1570 lbf

    Platen Upper:

    6 X 6 F/B in

    Platen Lower:

    6 X 6 L/R in

    TSlot Spacing:

    4 in

    Tap Switch:

    8-Step HI/Low

    Additonal Details:

    Heavy duty T-W Model ENE-18-50, 50 KVA, 440V. T-slotted platens top and bottom. Spot welding arms could be added. Original control removed and a complete strip and ReMan procedure is recommended. This would include the installation of a new or reconditioned control with programmable functions.

 
T. J. Snow, Company 120 Nowlin Lane, Chattanooga, TN 37421 | [email protected] 423-894-6234